Products
Dry Bulk
Dry Bulk Products
Application:
Designed specically for use on trailer tanks containing dry bulk products. If a system blockage
were to occur the valves are designed to open to atmosphere to help prevent the tank from
imploding.
Standards:
These valves come with a set vacuum tolerance of +/-0.5 HG, available in 3 body sizes:
1½" male NPT outlet (tank connection) x 1½" female NPT inlet (atmosphere)
2" male NPT outlet (atmosphere) x 2" female NPT inlet (tank connection)
3" female NPT outlet (tank connection) x 3" female NPT inlet (atmosphere)
Materials:
Bayloy body and bronze poppet
Features & Benets:
Available with a variety of vacuum settings, see chart below for model specic available pressure
settings. Customer should request set pressure at time of order.
Relieving capacity (SCFM) varies deponent upon model and pressure setting. See chart below,
or for specic relief rates please refer to our website or contact Dixon.
Installed bolt seal deters tampering
Bayloy body eliminates thread galling
1120
Valve
Series
Valve Outlet
(Tank Connection)
Valve Inlet
(Atmosphere)
Available Factory
Set Vacuum Range
(HG)
1
Set Pressure
Tolerance (PSI)
Relieving
Capacity
(SCFM)
2
1120/xx
1½" male NPT outlet
(tank connection)
1½" female NPT inlet (atmosphere) 6 to 24 +/- 0.5 HG 175 to 420
2120/xx
2" male NPT outlet
(tank connection)
2" female NPT inlet (atmosphere) 5 to 24 +/- 0.5 HG 280 to 600
3120/xx
3" female NPT outlet
(tank connection)
3" female NPT inlet (atmosphere) 11 to 25 +/- 0.5 HG 700 to 1350
2120 3120
¹ request the required pressure setting when ordering (xx refers to choice of pressure setting)
² relieving capacity (SCFM) varies with set pressure, for specic rates please refer to our website or contact Dixon
Vacuum Relief Valves
Trailer/Tank Mounted Air Relief Valves
* Customer adjustable by a further +/- 3 PSI. Settings below 9 PSI are obtainable by turning the valve adjustment screw.
Example for an 8 PSI setting the valve adjustment would be +4/-2, for 7 PSI +5/-1 and for 6 PSI +6/-0.
Settings above 30 PSI are obtainable by turning the valve adjustment screw. Example for a 31 PSI setting the valve adjust-
ment would be +2/-4, for 32 PSI +1/-5 and for 33 PSI +0/-6