800.355.19916 Dixon Bayco 2013
Products
Dry Bulk
Dry Bulk Products
Application:
Designed specically for use on trailer tanks containing dry bulk products. If a system blockage
were to occur the valves are designed to open to atmosphere to help prevent the tank from
imploding.
Standards:
These valves come with a set vacuum tolerance of +/-0.5 HG, available in 3 body sizes:
• 1½" male NPT outlet (tank connection) x 1½" female NPT inlet (atmosphere)
• 2" male NPT outlet (atmosphere) x 2" female NPT inlet (tank connection)
• 3" female NPT outlet (tank connection) x 3" female NPT inlet (atmosphere)
Materials:
Bayloy body and bronze poppet
Features & Benets:
• Available with a variety of vacuum settings, see chart below for model specic available pressure
settings. Customer should request set pressure at time of order.
• Relieving capacity (SCFM) varies deponent upon model and pressure setting. See chart below,
or for specic relief rates please refer to our website or contact Dixon.
• Installed bolt seal deters tampering
• Bayloy body eliminates thread galling
1120
Valve
Series
Valve Outlet
(Tank Connection)
Valve Inlet
(Atmosphere)
Available Factory
Set Vacuum Range
(HG)
1
Set Pressure
Tolerance (PSI)
Relieving
Capacity
(SCFM)
2
1120/xx
1½" male NPT outlet
(tank connection)
1½" female NPT inlet (atmosphere) 6 to 24 +/- 0.5 HG 175 to 420
2120/xx
2" male NPT outlet
(tank connection)
2" female NPT inlet (atmosphere) 5 to 24 +/- 0.5 HG 280 to 600
3120/xx
3" female NPT outlet
(tank connection)
3" female NPT inlet (atmosphere) 11 to 25 +/- 0.5 HG 700 to 1350
2120 3120
¹ request the required pressure setting when ordering (xx refers to choice of pressure setting)
² relieving capacity (SCFM) varies with set pressure, for specic rates please refer to our website or contact Dixon
Vacuum Relief Valves
Trailer/Tank Mounted Air Relief Valves
* Customer adjustable by a further +/- 3 PSI. Settings below 9 PSI are obtainable by turning the valve adjustment screw.
Example for an 8 PSI setting the valve adjustment would be +4/-2, for 7 PSI +5/-1 and for 6 PSI +6/-0.
Settings above 30 PSI are obtainable by turning the valve adjustment screw. Example for a 31 PSI setting the valve adjust-
ment would be +2/-4, for 32 PSI +1/-5 and for 33 PSI +0/-6
Air Relief Valve Settings
Pressure Relief Valves
Minimum and Maximum Settings
Vacuum Relief Valves
Minimum and Maximum Settings